Occurrence:
This following error message is displayed when attempting to convert UBC DCIP2D conductivity and chargeability file into Geosoft Grid files by going to Map > Import >UBC DCINV2D/IPINV2D Files:
Error calculating cell size and padding for mesh file *.msh
Followed by
Error importing UBC MSH file *** on line 1:Error reading value NLX
Resolution:
Instead of using the "Import UBC DCINV2D/IPINV2D Files" function, try using the voxel conversion tools to import the data:
- Go to Voxel > Conversions > UBC to Voxel
- Enter a name for the voxel file that will be created.
- For Model file, browse to and select {filename}.res.
- For MSH header file, browse to and select {filename}.msh.
- Open {filename}.res in a text editor to obtain the dummy value.
It may look something like 1.E+010. - Enter this as the Value to interpret as dummy.
- The data will open in the Voxel Viewer which is Read Only. Close this window.
- In the 3D Viewer > Add to 3D menu > Voxel > browse to the file that was created through the import.